18.5 To remove the top tray.

1. Complete sections 19.1 - 19.4
2. Lift out the Top tray and carefully place to one side.
There are no screws holding this tray inplace.
3. If glass liners have been fitted only, there will also
be an additional filler top tray to the rear, lift this up
also any place to the side. It is not held inplace by any
screws.
4. Replace in reverse order.

18.6 To remove the base tray.

1.Complete sections 19.1 - 19.5
2. Unscrew the base tray, then remove and place to
one side carefully.
3. Replace in reverse order.

18.7 To remove the burner assembly and tray.

1. Complete section 19.1 - 19.6
2. Isolate the gas supply at the inlet isolating 'T'
connector.
3. Support the inlet 'T' connector to avoid straining the
pipework and disconnect the appliance from the inlet
'T' connector.
4. Unscrew the burner tray from the convection box by
removing two locating screws.
5. Slide the burner tray unit clear of the convector box.
6. Replace in the reverse order.
NOTE: Checking the aeration setting of the burner.
1. The aeration shutter is factory set. It is important to ensure that the aeration
setting(s) are correct
2. Note: the 600RC/FS and 800RC/FS models burners
all use the aeration setting open at 4.5mm.
2. If the setting is not as shown, adjust the aeration
setting(s). To do this loosen the two aeration shutter
screws, slide the aeration shutter to the desired position
and tighten the screws.
©