INSTALLER GUIDE
6. Detach the burner tray from the
convection box by removing two locating
screws. Slide the burner tray forward and
clear of the convection box.
IMPORTANT
Before continuing with the installation
of this gas fire the aeration setting on
the burner must be checked. The
aeration is factory set and should not
require adjustment. (Ref: Page 40)
7. It is important that the inlet cover plate supplied in the
Accessory parts pack is fitted to cover the entry hole in the
inside rear of the convection box. The inlet cover plate has a
slot to allow the pipe to pass through its center. The slot is
larger than the 8mm pipe so the remaining open area MUST
be sealed with tape after the pipe is located.
8. This appliance is supplied with a flue restrictor this is for use where the flue
draught is excessive. There may however, be certain circumstances where closing
the restrictor causes the fire to fail the spillage test. In such cases the restrictor will
have to be returned to it supplied state of fully open. After any changes conduct the
spillage check again. The restrictor is prefitted (fully open) to the inside rear of the
convector box, if necessary loosen the three screws and slide upwards.The restrictor
has a limited travel so the outlet cannot be fully closed.
©