Eiiiiiiiildd - ICP DAS USA I-7530 User Manual

The uart to can bus converter
Hide thumbs Also See for I-7530:
Table of Contents

Advertisement

ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ
4.3 eIIIIIIIILDD...[CHK]<CR>
 Description: Send or receive an extended CAN data frame.
 Syntax: eIIIIIIIILDD...[CHK]<CR>
e
IIIIIIII
L
DD...
 Response: Valid command: No response
Invalid command: ?<Error Code><CR>
Note:
It is necessary to enable the "Error Response" function in the CAN
Converter Utility, in order to receive Syntax and/or communication
error information at the host PC.
 Example:
Command: e1234567851122334455<CR>
Send a CAN message with an extended data frame. ID=12345678,
DLC=5, data1=11, data2=22, data3=33, data4=44 and data5=55.
I-7530, I-7530-FT, I-7530A, I-7565 User's Manual (Version 1.3, Apr/2015) -------- 36
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Stands for the extended (2.0B) data frame.
29 bits Identifier (00000000~1FFFFFFF)
Data length (0~8)
Input data frame value according to the data length
(00~FF)