converter will start to transfer the UART message to the
CAN Bus.
* Pair Connection Command Timeout: Only the tM-7530 and
I-7530A-MR supports this function. The CAN timeout is used
to decide the transformation timing of the CAN messages to
the UART messages. After the CAN converter receives the
CAN message, it will not transfer the CAN message to UART
message until the time of the CAN timeout passes. If users
would like to transfer the CAN message to UART messages
immediately, set this value to 0. The function of the UART
timeout is similar with the CAN timeout. It is decide the
transformation timing of the UART messages to CAN
messages. Only the configuration of the end characters of the
UART message is none, the UART timeout is useful. After
receiving one character from the UART interface, the CAN
converter will not transfer the data until the time of the UART
timeout passes.
About details of the pair connection, please refer to the Appendix
E for reference.
 Save and default value button:
After finishing the configuration, users can click the button "Save
All Setting" to save the configuration in to the EEPROM of the
CAN converter. If users would like to recover the parameters to
the factory default, click "Load Default Setting" button to recover
all of the configuration parameters to be default value. Afterwards,
I-7530, I-7530-FT, I-7530A, I-7565 User's Manual (Version 1.3, Apr/2015) -------- 27