ICP DAS USA I-7530 User Manual page 42

The uart to can bus converter
Hide thumbs Also See for I-7530:
Table of Contents

Advertisement

ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ
 Response: A valid command will let the module write the RS-
232/RS-485/RS-422/USB parameters into the EEPROM
and then reboot the system.
Invalid command: ?<Error Code><CR>
Note:
It is necessary to enable the "Error Response" function in the CAN
Converter Utility, in order to receive Syntax and/or communication
error information at the host PC.
I-7565 supports only one 921600 baud rate on the firmware version
2.X or before.
 Example:
Command: P00B30000<CR>
Set the RS-232/RS-485/RS-422/USB baud rate=115.2K, data
bit=8, stop bit=1, none parity, no checksum and No error
responses into the CAN Converter module and then reboot the
CAN Converter module.
I-7530, I-7530-FT, I-7530A, I-7565 User's Manual (Version 1.3, Apr/2015) -------- 42