Serial Communication (SCOM) Interface
Installation in display
Connectorization
The remote control has either two or one 9 pin D-subs for communication. For systems with more
than one unit, the units are connected together through the unoccupied D-sub. It is regardless
which one is used, but normally COM-1 is connected to another unit, and COM-2 is connected to
the PC. On units with just one connector it is connected to the PC equipment for single
communication only.
Address
A display's address is set by a 5-bit dipswitch (red) on the backside of the display (own page in this
manual describes its location). Only bits 1-4 are currently in use. The position of bit 5 has no effect.
Address is adjusted according to the following table:
Address
Bit 1
0
Off
1
On
2
Off
3
On
4
Off
5
On
6
Off
7
On
8
Off
9
On
10
Off
11
On
12
Off
13
On
14
Off
15
On
Selecting communication mode:
RS-232
RS-485
Full duplex
Half duplex
These settings are normally carried out by manufacturer before delivery.
Communication Interface
IND100084-6
Bit 2
Bit
Off
Off
Off
Off
On
Off
On
Off
Off
On
Off
On
On
On
On
On
Off
Off
Off
Off
On
Off
On
Off
Off
On
Off
On
On
On
On
On
Communication mode (U5)
RS232
RS422/485
62
Bit
Off
Off
Off
Off
Off
Off
Off
Off
On
On
On
On
On
On
On
On
Duplex (U8)
-
Full (on)
Half (off)