6.4. CAN Error Counter Register
Bit
Symbol Value
7:0
TEC
14:8
REC
15
RP
31:16
-
I-2533CS-FD ( CAN/CAN FD to Single-mode Fiber Bridge ) User Manual (version 1.1.0)
Copyright © 2020 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
Transmit error counter
Current value of the transmit error counter (maximum value 255)
Receive error counter
Current value of the receive error counter (maximum value 127).
Receive error passive
Below error level. The receive counter is below the error passive
0
level of 128
At error level. The receive counter has reached the error passive
1
level of 128
-
Reserved
Description