3.2. Fiber Selection & Fiber Length
The specification of fiber cable used to connect the I-2533CS-FD is shown as
following table.
Single mode
The I-2533CS-FD allows maximum 30km fiber length for each kind of CAN baud
theoretically. Although the maximum fiber length has no relationship with the CAN baud
rate, but some fiber attributions, such as attenuation, still influence it. Higher attenuation
of fiber will reduce the transmission distance. User can use following table to know the
relationship between those two.
Table 3-2-2 The relationship between CAN baud rate and theoretical Fiber length
Module Name
I-2533CS-FD
Module Name
I-2533CS-FD
I-2533CS-FD ( CAN/CAN FD to Single-mode Fiber Bridge ) User Manual (version 1.1.0)
Copyright © 2020 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
Table 3-2-1 Specification of Fiber
Diameter [μm]
Type
(Core/Cladding)
8.3/125, 8.7/125,
9/125 or 10/125
Arbitration
bit rate (bps)
10 k ~ 1M
Table 3-2-3 Fiber Attenuation & Fiber Length
Attenuation
Fiber
[dB/km]
0.4
> 0.4
Wavelength [nm]
Data Phase
bit rate (bps)
100 k ~ 3M
Allowed Fiber length
Operating
1310
Allowed Fiber length
[km]
30
[km]
30
< 30