IMPORTANT SAFETY

Please read and follow these important instructions to help ensure your safety and the quality performance of your Kasco equip-
ment�
Use caution when dealing with any electrical and/or moving equipment�
Under NO CIRCUMSTANCE should anyone enter the water with the electrical equipment plugged in and/or in operation�
Kasco Aerating Fountains are intended for use with a Listed control panel having a GFCI protected receptacle, or field wiring
terminals and disconnect switch, or a timer with a disconnect for use with a GFCI receptacle� Control panels MUST be installed by
a qualified electrician. Ground Fault Circuit Interrupters (GFCIs) should be tested upon each installation and every month thereafter
to ensure proper operation�
Single-phase units are supplied with an internal grounding conductor and/or a grounding-type attachment plug� To reduce the risk
of electrical shock, be certain the unit is properly connected to the Kasco-supplied control panel (refer to the instructions included
with your control panel)�
NEVER run the unit out of the water� This will damage the seals and create a dangerous situation for the operator�
Use extreme caution around water, especially cold water, as in spring, fall, and winter, which poses a hazard in and of itself�
NEVER lift or drag the equipment by the power cords� If you need to pull the unit to the side of the pond, use the anchoring ropes�
Do not use boats that tip easily for installation and follow all boating safety rules and regulations, including wearing a PFD (Person-
al Flotation Device)�
Do not use waders in deep ponds/lakes or ponds/lakes with drop-offs, drastic slopes, or soft bottom material�
Control panels must be installed by a qualified electrician.
For more information regarding your control panel instructions, refer to your control panel owner's manual. A control panel must be
installed a minimum of 5 feet (3m in Canada) from the body of water unless separated from the body of water by a fence, wall, or
other permanent barrier that will make the unit inaccessible to persons in the water� A complete list of control panels can be found
in the
Accessories
section of kascomarine�com�
Additional Notes
During flotation operation, water is pulled from 360° around and directly below the unit. Keep these areas clear of debris as much as
possible to decrease frequency of screen cleaning�
UNIT SPECS & PATTERN SIZE
Model
Pattern Size
Height
2400VFX
5 ft�
3400VFX
5�5 ft�
3400HVFX
5�5 ft�
4400VFX
8 ft.
4400HVFX
8 ft.
2400 – 4400 VFX DECORATIVE AERATOR
Operating
Voltage
Amps
Width
15 ft�
110-120
5.6
21 ft�
110-120
7.3
21 ft�
208-240
3.7
26 ft.
110-120
11.3
26 ft.
208-240
5�7
Locked-Rotor
Control Panel
Amps
Connection
Single-Phase Units
12
C-25 plug in
18
C-25 plug in
9
Hardwire C-85 Plug into or hardwire C-85
40
C-25 plug in
20
Hardwire C-85 Plug into or hardwire C-85
3
Back to Contents
MANUAL
Unit Connection
Plug into C-25
Plug into C-25
Plug into C-25
884170 / 2021.1.1