MAINTENANCE RECOMMENDATIONS

Under NO CIRCUMSTANCE should anyone enter the water while a fountain is operating.
The following maintenance procedures can be utilized to ensure many years of quality performance from your Kasco equipment and
reduce the need for more costly repair work�
PROPER INSTALLATION: Proper installation of Kasco equipment will include a power source with ground fault protection� The control
panel included with the equipment has built-in ground fault protection for both the fountain and the lighting kit� Ground fault interrupters
are a safety feature that can also alert you to electrical leaks in the equipment� It is extremely important to test the GFI upon installation
and every month thereafter to ensure proper operation� If you have repeat, consistent trips of the ground fault device, the equipment
should be disconnected and removed from the water� The power cord should be inspected for damage, and you should contact your
distributor or contact Kasco Marine at 715-262-4488 or sales@kascomarine.com for further instructions. A complete list of control pan-
els can be found in the Accessories section of kascomarine�com�
OBSERVATION: Operating equipment should be observed on a regular basis (daily, if possible) for any reduction or variation in perfor-
mance� If a change in performance is observed, the equipment should be disconnected from power and inspected�
WINTER STORAGE: In regions where there is significant freezing in the wintertime, the equipment should be removed from the water
to protect it from the expansion pressure of ice� Aerators may keep some amount of ice open, but when water is thrust into the air it can
make the existing ice thicker. Storage over winter is best in a location that is out of the sun and cool, but above 32° F. Store unit upside
down if it will sit for a long period of time to ensure continued oil lubrication of seals; units that sit upright for many months or years have
a greater likelihood of seals drying out�
CLEANING: Aerators should be removed from the water at least once per year (at the end of the season in cold climates) to clean
the exterior of the system, especially the stainless-steel motor housing (can) that dissipates heat into the water� Any algae, calcium, or
other build-up will become an insulator that blocks heat transfer and may lead to overheating and damage� In warmer regions, the unit
should be removed and cleaned at least 2 – 3 times per year. In most cases, a power washer is sufficient if the unit and algae are still
wet�
SEAL AND OIL REPLACEMENT: This is a sealed motor assembly, and seals will wear out over time (similar to brake pads on a car)�
Replacement of the seals and a change of oil after three years may add longevity to the operation of the motor, saving you the cost of
more expensive repairs� In warmer climates where the aerator runs for a majority of the year or greater, it is wise to replace seals more
often�
ZINC ANODE: A sacrificial zinc anode is supplied on the shaft of all VFX Model aerators for protection from corrosion and electrolysis.
The zinc anode should be updated/replaced if reduced to half the original size or if white in color� Corrosion from electrolysis is more
commonly associated with saltwater or brackish water, but as a matter of precaution, it is important to periodically check the zinc anode
in all installations (at least every two to three months)�
Seal replacement and all other repair services should be performed by Kasco Marine or a Kasco-trained Authorized Repair Center� Any
alterations or changes made to Kasco units by an unauthorized source will void the warranty� This includes tampering with the unit,
power cord, and/or control panel. Contact Kasco Marine at 715-262-4488 or sales@kascomarine.com for additional information and
your closest Authorized Repair Center�