SAFETY FIRST
•
NEVER enter the water with the electrical equipment connected and/or in operation.
•
All electrical equipment must be Ground fault/leakage current protected. Use of a Ground fault
protective device (GFI, RCD, RCBB, or RCBO type device) is required as directed by local and national
codes.
•
Stay clear of all moving parts.
•
NEVER run the unit out of water. This will damage the equipment and pose a danger to the operator.
•
Use extreme caution around water, especially cold water.
•
NEVER lift or drag the unit by the power cord. Always use the ropes or mount to remove it from the
water.
•
Do not use waders in deep water or in areas with drop-offs, drastic slopes, or soft bottom material.
•
Do not use boats that tip easily for unit installation (such as canoes).
•
Follow all boating safety rules and regulations, including wearing a Personal Flotation Device.
•
The unit is supplied with an internal grounding conductor. To reduce the risk of electrical shock, be
certain that the unit is plugged in/connected to a circuit with ground fault protection.
•
Means for disconnection must be incorporated in the fixed wiring, in accordance with local and national
wiring rules.
•
Consult a qualified electrician for electrical installation.
UNIT SPECIFICATIONS
Model
HP
Voltage / Phase / Hz Amperage
2400EJF
1/2
3400EJF
3/4
WARNINGS:
Moving Machinery
OVERVIEW
230 / 1 / 50
2.2
230 / 1 / 50
3.5
WIRE SIZE
10m
2400EJF
1.5mm²
1.5mm²
3400EJF
1.5mm²
1.5mm²
Shock Hazard
Locked Rotor
Suggested Pond
Amps
5.3
9
Cord Length
30m
60m
90m
2.5mm²
2.5mm²
2.5mm²
2.5mm²
SMALL EJ SERIES FOUNTAIN MANUAL
Back to Contents
Min� Depth
Size (m²)
of Operation
1,000
38cm
1,350
45cm
2