Wasp Delta 4070 Industrial X Series Manual Of Use And Maintenance page 66

Hide thumbs Also See for Delta Wasp 4070 Industrial X Series:
Table of Contents

Advertisement

8
USE OF THE PRINTER
8
   P
remises
8.9. Multi-core: change extruder
The Multi-core system is a system that simplifies the configuration and use of different types of extruders on the
same machine.
Among the advantages it brings there are:
Compatibility with Zen and Flex extruders
Automatic recognition between double extruder and single extruder
Automatic setting of the optimal settings for each extruder.
DISASSEMBLE ZEN EXTRUDER
1. Perform the removal of the filament as described in paragraph 5.3 "First start"
2. Turn off the machine
3. Remove the central band
4. Cut the cable tie on the extruder
5. Remove delicately the connectors on the extruder
6. Remove PTFE pipes
7. Unscrew the 6 screws fizing the effector with the support arms with a 3mm Allen key
8. Remove the arms from the effector, with the help of a long flat screwdriver
9. Remove the whole extruder and store it with caution
66
fig 8-9 a
fig 8.9 b
© WASP S.r.l.