Ordinary Maintanance; Fan Filter; Arms Ball Joint; Extruder Fans - Wasp Delta 4070 Industrial X Series Manual Of Use And Maintenance

Hide thumbs Also See for Delta Wasp 4070 Industrial X Series:
Table of Contents

Advertisement

6
Ordinary and extraordinary maintanance
6
   P
remises

7.2. Ordinary maintanance

Periodic maintenance and correct use are essential factors to ensure the functionality, safe operation and
durability of the printer. The maintenance interventions and the required interventions are carried out by the
mechanical maintenance technician who must operate in compliance with the safety instructions contained in
this manual.
ATTENTION:
The maintenance operations must be carried out by disconnecting the printer from the power
source by unplugging the power plug.
NOTE:
In case of replacement of components during maintenance, they must be replaced with identical
and original components.
Part

Fan filter

Belts

Arms ball joint

Extruder fans

Elastic ropes

Sliders
Extruder
Ooze shield protection
Print bed
7.2.1. Fan filter
Verify and replace filter
To perform the verification, proceed as follows:
1. Remove the indicated filter;
2. If it turns out to have become gray, provide for its replacement or cleaning.
7.2.2. Arms ball joint
Lubrication
Check the movement / stiffness of the arm joints, if these are rigid, apply grease, using a brush.
7.2.3. Extruder fans
Check if working
Check the correct operation of the fans on the extruder and below the driver
7.2.4. Elastic ropes
Check damages
Check that the tensioning belts of the filament driver are not damaged.
40
Kind of intervention
Verify or replace
Tension control
Lubrication
Check if working
Check if damaged
Check plays
Cleaning
Replacement
Cleaning
Period
160 h
160 h
160 h
160 h
160 h
160 h
If clogged
If damaged
If too dirty
Procedure
Par. 7.2.1
/
Par. 7.2.2
Par. 7.2.3
Par 7.2.4
Par 7.2.5
Par 7.2.6
Par 7.2.8
Par 7.2.9
© WASP S.r.l.

Advertisement

Table of Contents
loading

Table of Contents