Wasp Delta 4070 Industrial X Series Manual Of Use And Maintenance page 44

Hide thumbs Also See for Delta Wasp 4070 Industrial X Series:
Table of Contents

Advertisement

Ordinary and extraordinary maintanance
   P
remises
7.3.1. Change nozzle Zen Extruder
Changing nozzle is only recommended when:
The print looks inconsistent due to a clogging
Necessity of changing nozzle's diameter
Necessity of using a nozzle in different
CHANGING NOZZLE
1. Turn on the printer
2. For removing the nozzle bring the chosen extruder at the previously used temperature, then wait few
seconds.
3. Perform the removal of the filament as described in paragraph 5.3 "First Start"
4. Remove the Ooze shied protection as described in paragraph 7.2.6 "Replacing Ooze shield protection"
5. Unscrew and remove the nozzle using the provided wrench, pay attention to hot surfaces.
6. Tighten back the new nozzle fixing it in its position.
7. Place back the Ooze shied protection as described in paragraph 7.2.6 "Replacing Ooze shield protection"
8. Perform the loading of the filament as described in paragraph 5.3 "First Start"
44