19.2.1.

Mechanism of screen update

It takes 0.5 seconds or less to update the state of the lamp and robot information, and the update which cannot
have been updated during that time is done after 0.5 seconds.
For example, it becomes the following if there are 15 information items to update, and 10 items can be dealt by
every 0.5 seconds.
While getting robot information, the signal is not outputted by tap or tap the button.
(1) The signal output by the button tapped or tapped is delayed 0.5 seconds or less.
(2) When parts increase, the update interval of the lamp and robot information becomes longer.
Get robot information (10 items)
Get robot information (5 items)
234
0.5 sec.
0.5 sec.
0.25 sec.
0.5 sec.