Interrelation of luminance and runtime
The projector can be operated at arbitrary brightness and duration of use by combining the settings of [MAX
LIGHT OUTPUT LEVEL], [LIGHT OUTPUT], and [CONSTANT MODE] in [BRIGHTNESS CONTROL SETUP].
Interrelation of luminance and runtime is as follows. Make the settings depending on your desired duration of use
and brightness of the projected image.
Values of the luminance and runtime are rough estimations.
r To set the projector based on the duration of use
Duration of use
[MAX LIGHT
(hour)
OUTPUT LEVEL]
20 000
100.0
24 000
100.0
28 000
100.0
32 000
100.0
36 000
100.0
40 000
100.0
r To set the projector based on luminance
[MAX LIGHT
Luminance (lm)
OUTPUT LEVEL]
20 000
100.0
18 000
100.0
16 000
100.0
14 000
100.0
12 000
100.0
10 000
100.0
Note
f Under influence of characteristics of each light source, conditions of use, installation environment, etc., the runtime may be shorter than the
estimation.
f The duration of use is referred to as the runtime when you use the projector successively. The duration of use is an estimated duration and
is not the warranty period.
f If the consolidated runtime of the projector exceeds 20 000 hours, replacement of the components inside the projector may be required. The
consolidated runtime can be confirmed in the [STATUS] screen. Refer to the [PROJECTOR SETUP] menu → [STATUS] for details.

[LIGHT OUTPUT]

Adjust the brightness of light source.
The setting is reflected when it is already set with "Initial setting (operation setting)" (x page 71) in the [INITIAL
SETTING] screen or with the [PROJECTOR SETUP] menu → [OPERATION SETTING]. The [LIGHT OUTPUT]
setting is synchronized with the [PROJECTOR SETUP] menu → [OPERATION SETTING] → [LIGHT OUTPUT].
The most recent setting is reflected in both items.
1)
Press as to select [LIGHT OUTPUT].
2)
Press qw to adjust.
Operation
Press w.
Press q.
*1 The upper limit of the adjustment range is the value set in the [PROJECTOR SETUP] menu → [OPERATION SETTING] → [MAX LIGHT
OUTPUT LEVEL].
Note
f [LIGHT OUTPUT] can be adjusted individually for each setting item of [OPERATING MODE].
172 - ENGLISH
Chapter 4 Settings — [PROJECTOR SETUP] menu
When [CONSTANT MODE] is set to [OFF]
[LIGHT OUTPUT]
(%)
(%)
100.0
100.0
90.0
75.4
64.0
55.0
When [CONSTANT MODE] is set to [OFF]
[LIGHT OUTPUT]
(%)
(%)
100.0
90.0
80.0
70.0
60.0
50.0
Brightness
The screen becomes brighter.
The screen becomes darker.
When [CONSTANT MODE] is set to [AUTO] or [PC]
[MAX LIGHT
Luminance (lm)
OUTPUT LEVEL]
(%)
20 000
100.0
20 000
100.0
18 000
100.0
15 100
100.0
12 800
100.0
11 000
100.0
When [CONSTANT MODE] is set to [AUTO] or [PC]
[MAX LIGHT
Runtime (hour)
OUTPUT LEVEL]
(%)
25 730
27 980
100.0
30 620
100.0
33 810
100.0
37 720
100.0
42 600
100.0
Adjustment
Runtime
The runtime becomes shorter.
The runtime becomes longer.
[LIGHT OUTPUT]
Luminance (lm)
(%)
67.2
13 400
63.5
12 700
60.0
12 000
57.0
11 400
54.2
10 800
51.6
10 300
[LIGHT OUTPUT]
Runtime (hour)
(%)
90.0
1 820
80.0
7 780
70.0
14 940
60.0
24 210
50.0
36 970
Range of adjustment
8.0 % - 100.0 %