3.1 Assembling gun
For the correct components, refer to "Component selection" on page 23.
Tools needed:
8mm / 12mm
1.
Flexlite GC 253G and GC 223 GMM: Insert the isolation ring in place.
2.
Attach the contact tip adapter and tighten it firmly in place. With Flexlite GC 253G and GC 223 GMM, use a span-
ner for tightening.
It is important to tighten the adapter properly to enable a tight connection of the contact tip to the gun.
3.
Attach the contact tip and secure it with a spanner.
4.
Attach the gas nozzle and hand-tighten it firmly in place.
© Kemppi
7
Flexlite GC
Operating manual - EN
1921860 / 2109