Figure 28 – Terminate Input Wiring – RTE PIR Motion Sensor
J18 5 4 3 2 1
Door Inputs - A
Common
1
2
3
4
5
6
7
8
Non-supervised
J18 – Jumper 5 & 4 = Off
PIR
RTE (Request to Exit) – ½ second pulse
Determines the amount of time the output relays will energize when motion is detected.
Single end of line
J18 – Jumper 5 = Off
KI-00131E-07-11
Keyscan Technical Guide (PC109x - 04.12)
J18 – pins 5 & 4 set supervision type (Jumper setting
applies to all Door Inputs, RTE Inputs, and AUX Inputs.)
Cut View of CA8500B
RTE Inputs - B
Common
1
2
3
4
5
6
7
8
COM
NO
Lens
PIR (Request To Exit)
NO = Normally Open
to
Request
to Exit
supervision
Jumper 4 = On
1K
NO
Double end of line
supervision
J18 Jumper 5 & 4 = On
AUX Inputs - C
Common
AUX Inputs - D
1
2
3
4
5
6
7
8
9
10
11
12
Notes
Diagram illustrates CA8500B. Connections also apply to
CA250B & CA4500B.
- CA250B – up to 2 Request to Exits
- CA4500B – up to 4 Request to Exits
- CA8500B – up to 8 Request to Exits
to Common Return
COM
Lens
to
Request
to Exit
1K
3K
COM
NO
Lens
Common
AUX Inputs - E
13
14
15
16
17
18
19
20
21
22
23
24
to Common Return
41