Figure 29 – Terminate Input Wiring RTE - PIR & Push Button
J18 5 4 3 2 1
Door Inputs - A
1
2
3
4
5
6
7
8
No supervision
J18 Jumper 5 & 4 = Off
RTE
Push Button
NO
COM
Note
If using supervision, it is only required on the device farthest from the ACU
terminal. Example shows supervision on RTE Push Button.
Single end of line supervision
J18 – Jumper 5 = Off
Jumper 4 = On
KI-00132E-07-11
Keyscan Technical Guide (PC109x - 04.12)
J18 – pins 5 & 4 set supervision type (Jumper setting
applies to all Door Inputs, RTE Inputs, and AUX Inputs.)
Cut View of CA8500B
Common
RTE Inputs - B
Common
1
2
3
4
5
8
6
7
COM
NO
Lens
PIR (Request To Exit)
NO = Normally Open
"Two devices wired in
parallel to each other"
NO = Normally Open
to Request
to Exit
1K
NO
COM
to Common Return
AUX Inputs - C
Common
AUX Inputs - D
1
2
3
4
5
8
9
10
11
12
6
7
PIR
Motion Sensor RTE (Request to Exit) – ½ second
pulse
Determines the amount of time the output relays
will energize when motion is detected.
Notes
Diagram illustrates CA8500B. Connections
also apply to CA250B & CA4500B.
- CA250B – up to 2 Request to Exits
- CA450B – up to 4 Request to Exits
- CA8500B – up to 8 Request to Exits
Double end of line supervision
J18 Jumper 5 & 4 = On
Common
AUX Inputs - E
13
16
17
18
19
20
21
24
14
15
22
23
to Request
to Exit
1K
NO
3K
COM
to Common Return
42