Figure 83 - Power Supply Wiring - Keyscan CA250 Series Technical Manual

Hide thumbs Also See for CA250 Series:
Table of Contents

Advertisement

Keyscan p/n
- CAS6101 &
- CAS6102
ACU 16V 40VA
or
ACU 16.5V 37VA
Transformer
Primary
110 VAC
AC
AC
AUX/RDR
CAS6105 Cable
Use Keyscan p/n CAS6105 plug-in cable included with
DPS15 to connect control board with power supply.
Diagram shows cut view of CA 8000 control board. The
PSC1 terminal is in the same location on all CA & EC
control boards.
Note
The CAS6105 cable can only be plugged into the PSC1
terminal when aligned in the correct orientation.
KI-00192E-01-12
Keyscan Technical Guide (PC109x - 04.12)
Figure 83 – Power Supply Wiring
Black
-
12V
Battery
(fully-charged)
Red
+
-
+
FAIL -
+
BATT
AUX/RDR
EGND
PSC1
AUX/RDR + 12V
DPS-15
Dual Power Supply
AC
AUX/RDR
Important
The PC109x control board emits an intermittent beep if:
A) a back-up battery is not connected
B) two (2) transformers are not connected
ACU Ground
Lug
Connect to PSC1 on
-
+
FAIL
AC
AC
ACU
ACU
ACU + 12V
AC
ACU
Connect to PSC1
on control board.
ACU 16V 40VA
or
Do not
ACU 16.5V 37VA
mount the
Transformer
transformers
inside the
ACU metal
enclosure.
Primary
110 VAC
DPS15.
Keyscan p/n
- CAS6105
READER 8
PC109x
Control Board
PSC1
READER PWR
-
+
FAIL
-
+
FAIL
ACU PWR
110

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ca4500 seriesCa8500 seriesEc1500 seriesEc2500 series

Table of Contents