Figure 32 - Terminate Floor Wiring Ec2500B - Keyscan CA250 Series Technical Manual

Hide thumbs Also See for CA250 Series:
Table of Contents

Advertisement

EC2500B
Control
Board
Cut View
OCB-8
Current – 230 mA
Relays – Form C contacts
OCB-8 ribbon cable
connects to CONTROL 1
(Floors 1 to 8)
-
TAMPER TB3
SWITCH
CTS
DTR
DCD
RD
TD
GND
RS-232 (COM4)
KI-00135E-07-11
Keyscan Technical Guide (PC109x - 04.12)
Figure 32 – Terminate Floor Wiring EC2500B
K8
– 5 A / 30 VDC
– 10 A / 24 VAC
Normal
J1
Floor
to
Output
J8
Reversed
Set J1 to J8 on Reversed & J9 on EXT PWR
ACU EXT
Floor
J9
PWR
Output
GND
12V
K1
Fire Panel
trips on alarm
N.C.
-
AUX/RDR 12 V or
ACU 12 V
on DPS-15
K7
K6
K5
Floor
Floor
Floor
Output
Output
Output
8
5
7
6
J7
J6
J8
J1
J2
J3
Floor
Floor
Floor
Output
Output
Output
3
4
1
2
K2
K3
K4
EC2000 Control / Floor Output Assignments
Control 1 – OCB-8: Cab A - Floor Outputs 1 – 8
Control 2 – OCB-8: Cab A - Floor Outputs 9 – 16* (optional)
Control 3 – OCB-8: Cab B - Floor Outputs 1 – 8
Control 4 – OCB-8: Cab B - Floor Outputs 9 – 16* (optional)
* OCB-8s must be purchased separately.
Ensure all elevator hardware complies with all fire code
regulations.
connects to
common on
elevator control
circuit
J5
J4
connects to
floor call button
46

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ca4500 seriesCa8500 seriesEc1500 seriesEc2500 series

Table of Contents