Figure 114 – K-RX Single Reader Connections - Channel B to ACU
ACU Ground Lug
KI-00218E-07-11
Keyscan Technical Guide (PC109x - 04.12)
D7
-
RANGE
D6
BUZ1
Receiver wired for Channel B
Active Transmitter Button
- Jumper OFF J1 – Button 2
- Jumper ON J1 – Button 4
For single channel
1
application Blue and
Brown not used.
Isolate and tape
back separately.
Shield
C1
LED D1
(BEEP)
WHT
Reader terminal on control board
Open: Buttons 1/2
Closed: Buttons 3/4
J1
+
LED/Beeper
Control
J5
2
3
4
5
6
7
Shield – Isolate
and tape back.
3 pairs shielded 18 AWG
maximum 500 ft (152.4 m)
D0
PWR
GND
GRN
RED
BLK
148