Figure 109 - Indala Pxk 501 Wiring - Keyscan CA250 Series Technical Manual

Hide thumbs Also See for CA250 Series:
Table of Contents

Advertisement

Shield not connected.
Isolate with electrical tape.
ACU
Ground
Lug
KI-00213E-07-11
Note on Indala PXK 501 Wiring
Reader/Keypad/LED ordered as 8 bit burst – example FP5061B-8 Bit Burst (Red only)
Keyscan Technical Guide (PC109x - 04.12)
Figure 109 – Indala PXK 501 Wiring
1
2
4
5
7
8
*
0
Shield
C1
LED D1
D0
(BEEP)
WHT
GRN
Reader terminal on control board
3
6
9
#
Blue used for pre-alert otherwise
isolate and tape back.
If connecting external sound device,
see Pre-Alert Relay Option or refer to
ACU cut sheet enclosed with panel
for ACU/OCB8 relay assignments.
Shield not connected.
Isolate with electrical tape.
6 conductors - shielded 22 AWG
Maximum 500 ft (152.4 m)
PWR
GND
RED
BLK