Figure 113 – K-RX Single Reader Connections - Channel A to ACU
application Blue and Brown
not used. Isolate and tape
ACU Ground Lug
KI-00217E-07-11
Keyscan Technical Guide (PC109x - 04.12)
D7
-
+
RANGE
D6
BUZ1
Receiver wired for Channel A
Active Transmitter Button
- Jumper OFF J1 – Button 1
- Jumper ON J1 – Button 3
1
2
For single channel
back separately.
Shield
C1
LED D1
(BEEP)
WHT
Reader terminal on control board
Open: Buttons 1/2
Closed: Buttons 3/4
J1
LED/Beeper
Control
J5
3
4
5
6
7
Shield – Isolate
and tape back.
3 pairs shielded 18 AWG
Maximum - 500 ft (152.4 m)
D0
PWR
GND
GRN
RED
BLK
147