Figure 38 - Terminate Input Wiring - Rte Pir Motion Sensor - Keyscan CA250 Series Technical Manual

Hide thumbs Also See for CA250 Series:
Table of Contents

Advertisement

Figure 38 – Terminate Input Wiring – RTE PIR Motion Sensor
Door Inputs - A
Common
1
2
3
4
5
6
7
8
NO = Normally Open
Non-supervised
PIR
RTE (Request to Exit) – ½ second pulse
Determines the amount of time the output relays will energize when motion is detected.
Supervision level set in Client software:
System VII & Vantage – Site Unit Setup
Aurora – Hardware Setup
Supervision level applied to all door inputs, RTE inputs, and auxiliary inputs.
Single end of line
supervision
KI-00131E-10-13
Keyscan Inc. – Technical Guide (PC109x - 07.15)
Cut View of CA8500B
RTE Inputs - B
Common
AUX Inputs - C
1
2
3
4
5
8
1
2
3
6
7
COM
NO
Lens
PIR (Request To Exit)
to
Request
to Exit
1K
NO
Double end of line
supervision
Common
AUX Inputs - D
4
5
8
9
10
11
12
13
6
7
14
15
Notes
Diagram illustrates CA8500B. Connections also apply to
CA250B & CA4500B.
- CA250B – up to 2 Request to Exits
- CA4500B – up to 4 Request to Exits
- CA8500B – up to 8 Request to Exits
to Common Return
COM
Lens
to
Request
to Exit
to Common Return
1K
3K
COM
NO
Lens
Common
AUX Inputs - E
16
17
18
19
20
21
24
22
23
57