Figure 61 - Single Acu Communication - Netcom2 Or Netcom6/Cpb-10-2 - Keyscan CA250 Series Technical Manual

Hide thumbs Also See for CA250 Series:
Table of Contents

Advertisement

Figure 61 – Single ACU Communication - NETCOM2 or NETCOM6/CPB-10-2
Parts List
- RS-232 Data Cable
- Control Board
- PC
- CPB-10-2
- NETCOM 2 or NETCOM6
- 10/100 Base-T Cable
12VDC Power Adaptor
(NETCOM2H or NETCOM6H)
+ -
12VDC
12VDC
power adaptor
NETCOM2 or
NETCOM6
Reset
Button
Current Draw
270 mA
RJ45
Jack
to network
10/100 Base-T
NETCOM LED Legend
- RS232 indicates 9-pin terminal
connected
- RX LED indicates PC polling
ACU/ECU
- TX LED indicates ACU/ECU
replying to PC
- ON LED indicates unit
receiving power
KI-00164E-07-11
Note
If the NETCOM2 or NETCOM6 is mounted in the metal enclosure, the shield of the serial cable may be
connected to GND as shown. If the NETCOM2 or NETCOM6 is mounted outside the metal enclosure the
shield must be insulated and connected directly to the metal enclosure ground lug. See Grounding
Communication Cable Shield.
Keyscan Technical Guide (PC109x - 04.12)
Host PC with
Communication Manager
12VDC to DPS15
(NETCOM 2 or
NETCOM6)
RX TX
RS-232
ON
LEDs
LEDs
I/O
DTR
DCD
RD
9-pin Male
Black
Connector
TD
Red
GND
Green
Either
or
RS - 232
22 AWG shielded cable
Maximum - 100 FT (30 m)
to
network
CPB/CB MODULE
(COM4)
Control Board
(PC 109x)
H1
ECM/GCM MODULE
H2
(COM2 & COM3)
17
18
19
20
21
22
23
24
Common
AUX Inputs - E
Brown & White not
used. Tape back.
Use either the 9-
pin connector or
the terminal block.
TX LED
Do not use both to
connect to the
CPB-10-2.
Jumper
ON
J1
J1
Shield & Green
Connect CPB-10-2 ribbon cable to
CPB/CB MODULE on control board.
SYSTEM CONFIG.
J16 -
A B C D E F
G
Jumper ON J16-G to activate
CPB/CB MODULE (H1).
CPB-10-2
Current Draw - 40 mA
GND
TD RD DCD GND R
T
B DTR CTS
Brown & White not
used. Tape back.
H
RX LED
84

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ca4500 seriesCa8500 seriesEc1500 seriesEc2500 series