Appendix F -Wieex2 & Cwieex2; Table 28 - Wieex2 & Cwieex2; Table 29 - Wieex2/Cwieex2 Power Requirements - Keyscan CA250 Series Technical Manual

Hide thumbs Also See for CA250 Series:
Table of Contents

Advertisement

Appendix F –WIEEX2 &
CWIEEX2
Appendix F reviews general information, installation guidelines, and connection diagrams for Keyscan RS485
Wiegand Extenders (WIEEX2) and COAX Wiegand Extenders (CWIEEX2). Wiegand extenders are used on doors
and readers that exceed the 500 feet maximum distance from the ACU. When installing the CWIEEX2 &
WIEEX2 extenders please check the version and observe the corresponding wiring diagram as indicated below.
Each type of Wiegand extender – CWIEEX2 and WIEEX2 – includes 1 transmitter and 1 receiver. The following
additional components may be required to complete the installation of Wiegand extenders:
12VDC 1Amp power supply with battery backup
mounting interface enclosure
Important
Do not mix CWIEEX2 or WIEEX2 (firmware 6.00 or higher) receivers and transmitters with previous
generation CWIEEX or WIEEX (firmware 5.03 or lower) receivers and transmitters.
WIEEX2 & CWIEEX2 Functions
The following table outlines the functions and capabilities of CWIEEX2 and WIEEX2 extenders.
CWIEEX2 / WIEEX2
CWIEEX2 or WIEEX2 – (firmware 6.00 or higher)
Unit
WIEEX2 Transmitter (Tx)
WIEEX2 Receiver (Rx)
CWIEEX2 Transmitter (Tx)
CWIEEX2 Receiver (Rx)
OCB-8
Keyscan Technical Guide (PC109x - 04.12)
Table 28 – WIEEX2 & CWIEEX2
Table 29 – WIEEX2/CWIEEX2 Power Requirements
Power
Notes
12 VDC, 50 mA
12 VDC, 50 mA
12 VDC, 50 mA
12 VDC, 50 mA
12 VDC, 230 mA
Optional – An OCB8 is required when not switching a 12VDC door lock
or gate operator. See Figure 122 – WIEEX2 to OCB-8 Cable Connection
on page 159.
Functions/Capabilities
- 26 bits to 80 bits
- multi-baud rates 9,600 & 19,200
- supports Present3
- PIN keypad transmission
- 4 & 8 bit burst