Maintenance and care
After 50 operating hours
5.3
HYDRAULIC
Service interval
First inspection after
25 operating hours
All 50 operating hours
5150.0022+5150.0023 (41500820)
Retighten all 5 mounting nuts (M7) at the exhaust silencer 18-20 Nm.
Kubota D1105
Sequence for tightening torque: see marking
Maintenance work
●
Control and tighten all hydraulic thread joints and connection.
(The implementation is only allowed by an expert).
●
Tighten all hydraulic connections.
●
Check the hydraulic system for leaks.
●
Check the hydraulic oil filter, clean it if necessary (if available).
●
Check the hydraulic oil and replace it in accordance to the manufacturer information
(recommended hydraulic oil: HLP 46 according to DIN 51524 – 51535).
●
Check the hydraulic hoses for breaks and abrasion.
Only specified types of oil may be used!
-
V3
26 / 36
GB