Troubleshooting - Assa Abloy Rixson Smok-Chek VI Installation And Instruction Manual

Table of Contents

Advertisement

PROGRAMMING RF REMOTE RECEIVER UNITS
DIP SWITCH SETTINGS
# 1
DESCRIPTION
OFF
Pulse Relay
ON
Toggle Relay
# 2
DESCRIPTION
OFF
0.5 sec Hold Time
ON
10 sec Hold Time
HAND HELD CONFIGURATION
1.
Set dip switches on the receiver to the desired activation cycle (dip switch 1 -Toggle or Pulse and dip switch 2 - 0.5s or 10s hold).
2.
Press either Learn w/Delay Button or Learn w/No Delay Button on the receiver depending on the activation requirements
(If delay learn is selected, adjust potentiometer to counterclockwise limit, 0 second delay). After learn cycle is complete, adjust
potentiometer to desired delay time (0-30 sec).
3.
Depress transmitter button repeatedly until Blue LED on the receiver illuminates (indicating reception of signal from transmitter).
NOTE: Repeat Steps 2-3 to program additional transmitters.
4.
To test the system, depress transmitter button (Red LED on Transmitter will illuminate) and observe that the Blue LED illuminates on the
receiver. This indicates that the relay has been activated.
PUSH PLATE CONFIGURATION
1.
Before beginning, it is easiest to have already prepared the installation of the pushplate.
2.
Connect the wires from the transmitter to the NO and COM contacts of the pushplates switch.
3.
Follow Steps 1-4 (Hand-Held Configuration); depress the pushplate to activate the transmitter.
4.
Attach the transmitter to the inside of the electrical box and complete the installation.
REMOVING TRANSMITTER CODE(S)
SINGLE TRANSMITTER CODE
1. Press both DELAY and NO DELAY BUTTONS simultaneously until Red LED flashes once (approximately 1 second).
2. Press transmitter button twice within 10 seconds and the transmitter code will be deleted.
ALL TRANSMITTER CODES
1. Press and hold both DELAY and NO DELAY BUTTONS simultaneously until Blue LED illuminates then release (approximately 10
seconds).

Troubleshooting

SYMPTOMS
Door does not hold open.
Door holds open but at the wrong angle.
Door not closing when Test/Reset switch
depressed. (Detectored units only)
SYMPTOMS
Red LED flashes on RF unit and can't program
receiver.
Receiver intermittently doesn't receive the
transmitter signal.
For problems not listed here, see page 16 for Technical Product Support Contact info.
Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
FUNCTION
Press the transmitter once and the relay will be active momentarily.
Press the transmitter once and the relay output is active indefinitely,
press it again and the relay will de-energize indefinitely.
FUNCTION (Pulse Mode Only)
Relay will remain active 0.5 second after the loss of activation.
Relay will remain active 10 seconds after the loss of activation.
DETECTORED AND NON-DETECTORED UNITS
PROBABLE
No power to unit.
Loose wire connection.
Cam switch not engaged.
Cam switch engaged too early or too late.
Cam switch shorted.
Wiring incorrect.
Short circuit across Test/Reset switch.
RF UNITS
PROBABLE
Push plate stuck or faulty transmitter.
Receiver antenna wire is too short
CAUSE
Check input voltage: 24VDC or 120VAC
Inspect wiring for loose connections.
Adjust Cam position (see pg. 6 or 11)
Adjust Cam position (see pg. 6 or 11)
Inspect Cam switch wiring for short circuit.
Inspect wiring (see pg.13-15).
Inspect Test/Reset switch for short circuit.
CAUSE
Disconnect each push plate or remove batteries until
LED goes out. Replace faulty push plate.
Add 6 3/4' lengths of wire to antenna until it receives
signal.
15
RIXSON
ASSA ABLOY
ON
ON
1 2
1 2
In Toggle Setting (1-ON), the Hold Time
is inactive. Either setting for #2 dip
switch will have the same result.
ON
ON
1 2
1 2
0.5 second
10 second
Pulse Setting
Pulse Setting
ANTENNA WIRE
BLUE LED
RED LED
TERMINAL
STRIP
DIP
SWITCH
LEARN WITH
DELAY
DELAY BUTTON
POTENTIOMETER
(Time Adjustment)
CORRECTIVE
ACTION
CORRECTIVE
ACTION
80-9372-0100-015 (02-14)
®
LEARN
W/O DELAY
BUTTON

Advertisement

Table of Contents
loading

Table of Contents