Table of Contents
loading

Summary of Contents for Assa Abloy RD3

  • Page 1 Original instructions User Manual Entrance Systems Revolving Doors ASSA ABLOY RD3, RD4 (CDC 4)
  • Page 2: Table Of Contents

    Product liability ........................... Warranty ..............................Service ..............................Intended use ............................Technical specification ........................How the ASSA ABLOY RD3 and ASSA ABLOY RD4 work ............Main parts .............................. Settings and operation PCD ......................General information PCD ..................Information prompts on PCD display ..............
  • Page 3 Quick guide changing operating mode ..................Other products from ASSA ABLOY Entrance Systems ............Declaration of conformity ........................ ASSA ABLOY as word and logo are trademarks owned by the ASSA ABLOY Group © ASSA ABLOY Entrance Systems, 2020 Technical data subject to change without notice.
  • Page 4: Instructions For Safe Operation

    Instructions for safe operation Failure to observe the information in this manual may result in personal injury or damage to equipment. To reduce the risk of injury of persons - use this door set only as a pedestrian door. Do not use the equipment if repair or adjustment is necessary.
  • Page 5: Congratulations On Your New Automatic Door

    Congratulations on your new automatic door! ASSA ABLOY Entrance Systems AB has developed automatic doors for more than 50 years. State-of- the-art technology and carefully tested materials and components provide you with a superior product. As with all other technical products, your automatic door requires periodic maintenance and service.
  • Page 6: Warranty

    Warranty ASSA ABLOY Entrance Systems warrants its products to be free from defects in material and work- manship under intended use and service for a warranty time of 12 months, beginning at time of delivery. This warranty extends only to the original buyer of the equipment.
  • Page 7: Intended Use

    Intended use The ASSA ABLOY RD3 and ASSA ABLOY RD4 are automatic revolving doors developed to provide draught free access to buildings. The door is designed to offer continuous use, a high degree of safety and maximum lifetime. The system is self-adjusting to the effects caused by normal variations in the weather conditions and to minor friction changes caused by e.g.
  • Page 8: Main Parts

    Main parts FU NC FU NC DA TA DA TA ↑ ↑ – – ↓ ↓ FUNC FUNC DATA DATA ↑ ↑ ↓ – – ↓ ILL-02335 Description Push button inside, the door will rotate 360°(option) Main control unit CDC 4 (behind fascia sheets) Vertical presence photocell sensor PDR (option) Dust protection roof (max.
  • Page 9: Settings And Operation Pcd

    ON/OFF switch in OFF position. Service request. Call ASSA ABLOY Entrance Systems FUNC for service. Real time operation ON, see "Real time operation" on page 13. DATA EAA156 The door configuration must be set by ASSA ABLOY Entrance Systems Service technicians. 1003090-en-12.0 Issue 2020-10-09...
  • Page 10: Access Code

    Access code To be able to operate the PCD it is required to login with an access code. Login on the PCD Press # to clear the display. Enter the access code 1234. The display shows ==. Press # to confirm the input. If the access code is correct the display shows LI (Login) 0 1 (Level 01)
  • Page 11: Changing Operating Mode

    Key impulse switch (option) If the door is locked with the ON/OFF switch it can be opened with a key switch (ask your local ASSA ABLOY Entrance Systems Service). When the key switch is activated, the door unlocks, runs 360º and locks again.
  • Page 12 The different operating modes Locked (Off) 01 The door rotates to its home position. If an electromechanical lock is fitted, the lock is activated. The door can be opened with the key impulse switch, see Key impulse switch (option) on page Note! If the door is placed in an escape route, selecting operating mode Locked or setting the ON/OFF switch in the OFF (0) position, disables by default the escape function.
  • Page 13: Real Time Operation

    Real time operation Programming of real time operation must be done by ASSA ABLOY Entrance Systems service technicians. Fill in form on next page. The CDC-system has three different day schedules. Each day schedule may contain up to 10 different operating modes. The week schedule informs the system of which day schedule to run and in what order during a week.
  • Page 14 Day schedule Day schedule 1 Day schedule 2 Day schedule 3 Week schedule Week day Schedule Monday Tuesday Wednesday Thursday Friday Saturday Sunday Exceptions Start exception End exception Exception schedule Issue 2020-10-09 1003090-en-12.0...
  • Page 15 Read speed settings Type F3. The display shows S1. Use ↑ or ↓ to select setpoint number to read. Press C to leave the menu. ↑ ↓ FUNC DATA EAA254 Setpoint Description Setpoint value High speed setpoint 1.0-6.0 rpm Low (handicap) speed setpoint 0.2-2.5 rpm Creep speed setpoint Fixed at 0.5 rpm...
  • Page 16: Safety

    Safety The safety systems are monitored to ensure the high safety level of the door. The condition of the safety equipment is periodically tested. This monitoring is made during normal running conditions and it does not affect the normal day-to-day operations of the door. Safety devices on the door Standard Description...
  • Page 17: Pressure Sensitive Safety Edges

    Pressure sensitive safety edges Pressure sensitive safety edges on the drum edges. These stop the rotation if compressed. When the obstacle is removed, the rotation continues. Force sensitive door leaves If the system detects an obstacle blocking the door, the motor is de-energized. The door makes three attempts to start with two seconds pause between each attempt and then waits another 30 seconds before a final attempt is made.
  • Page 18: Regular Safety Checks

    Note! If the door is placed in an escape route, tests must be performed regularly by trained personnel or fire department, according to local laws. Contact your ASSA ABLOY Entrance Systems service representative. For contact information, see last page. Issue 2020-10-09...
  • Page 19 CLEANING The best way to remove dust and dirt from the ASSA ABLOY RD3 and ASSA ABLOY RD4 and to maintain the quality of the enamel layer, the surfaces should be cleaned three times/year (once/four months period) with gentle (pH 5-9), non-polishing detergent and water. Use a soft non-abrasive sponge.
  • Page 20 ASSA ABLOY Entrance Systems door sticker: Mandatory, if applicable to highlight the presence of the glass (applied to all glass sections that are moving). Automatic door Contact your ASSA ABLOY Entrance Systems service representative. For contact information, see last page. Issue 2020-10-09 1003090-en-12.0...
  • Page 21: Troubleshooting

    Settings and operation PCD on page Check that there are no objects in the safety detection zone. Check that nothing is jammed beneath the door. If the problem continues, please contact your ASSA ABLOY Entrance Systems representative. 1003090-en-12.0 Issue 2020-10-09...
  • Page 22: Supervision System

    Supervision system The ASSA ABLOY RD3 and ASSA ABLOY RD4 have a built-in supervision system. If an error occurs, the PCD display will show an error or status code. During normal operation the display will show “ON”. To reset the door to normal operation after an error code, press C on the PCD. See code list below.
  • Page 23: Service/Maintenance

    (PRA-0003) available. These are used together. The table below shows the recommended interval in revolutions, when to replace parts during preventive maintenance. Talk to your ASSA ABLOY Entrance Systems representative to learn more about our service offering. Minimum maintenance interval of once a year. See EN16005.
  • Page 24: Remote Control Operation

    Remote Control Operation To operate the door and perform service checks, the CDC system can be connected to a computer via the RS 232 connection COM port. Ask your local ASSA ABLOY Entrance Systems distributor for more information. Com. port Com.port...
  • Page 25: Communication On/Off

    Logout ? (Y/N) Press Y to logout or N to return to the main menu. Main menu CDC Main Menu Door Type : RD3/4 - CDC42 HC11 SW Release : Ver 1.01.39 P1 #7CD3 2017-11-06 M16C SW Release : Ver 1.1.7...
  • Page 26: Door Operation

    Door operation CDC Door Operation Page Error/Status Display: Operating Mode: Door Speed (RPM*10): Revolution Counter: Date & Time: Monday 2017-11-06 08:24:29 Operating modes: 1 : Lock Door 2 : Auto = Start from open position 6 : Continuous Rotation 7 : Manual Operation Press function key: C : Error Clear I : Key Impulse...
  • Page 27: Options

    Options Even though the ASSA ABLOY RD3 and ASSA ABLOY RD4 are installed to comply with all applicable safety regulations, it is possible to enhance safety/comfort with the following add-ons (please contact your local ASSA ABLOY Entrance Systems company for detailed description).
  • Page 28: Pressure Sensitive Safety Edges Placed On The Door Leaves

    Pressure sensitive safety edges placed on the door leaves If one of the safety edges, mounted on the door leaves, is compressed, the door stops. When the obstacle is removed, the rotation starts. ILL-00056 Infrared presence sensing system Installed on the top of the door leaves-provides safety over the whole height of the door. If the sensor detects an obstacle the door stops or reduces speed to 0.5 rpm (configurable).
  • Page 29: Vertical Presence Photocell Sensor Pdr

    Vertical presence photocell sensor PDR Vertical presence photocell sensor PDR located above the entrance on inner and outer sides. If the beam is broken in the safety zone (approx. 25° from the drum edge) the door stops. When the obstacle is removed the rotation starts. Push button for disabled Push button to reduce speed of the door.
  • Page 30: Accessories

    Accessories Rotation brake (lock) Automatic activation (configurable) of the rotation brake in the standby position, prevents door rotation (e.g. from being manually pushed or by strong wind) when there is no signal from the activ- ation units. The brake can also be activated with a key switch or push button for immediate stop of the door.
  • Page 31: Night Closing Door Ncd

    Night closing door NCD Two versions are available: manually operated automatically operated Reception panel The reception panel contains a Program Control Device (PCD), a key impulse and an emergency stop button. The key impulse makes the door rotate 360º. The maximum cable distance from the door to the reception panel is 100 m.
  • Page 32: Quick Guide Changing Operating Mode

    Quick guide changing operating mode FUNC DATA ↑ – ↓ #Access code# #Access code# FUNC FUNC DATA DATA ↑ ↑ – – ↓ ↓ FUNC FUNC FUNC DATA DATA DATA ↑ ↑ ↑ – ↓ – – ↓ ↓ FUNC FUNC DATA DATA...
  • Page 33: Other Products From Assa Abloy Entrance Systems

    Other products from ASSA ABLOY Entrance Systems Door Systems Vertical lifting fabric doors Balance doors Dock levelers Air curtains Dock shelters Sliding doors Folding doors Swing doors High speed doors Automatic and manual activation units Loadhouses Overhead sectional doors Service such as preventive maintenance and upgrade programs, emergency repairs, service advice and door management 1003090-en-12.0...
  • Page 34: Declaration Of Conformity

    Other standards or technical specifications, which have been applied: IEC 60335-1 ed. 5:2010 IEC 60335-2-103 ed. 2:2006+A1:2010 EN 1627:2011 Class RC3 Certificate issued by a notified or competent body (for full address, please contact ASSA ABLOY Entrance Systems AB) concerning the equipment: BY/112 02.01. 020 08532 SC0834-14 TÜV B 058029 0045...
  • Page 36 Building on the long-term success of the Besam, Crawford, Albany and Megadoor brands, we offer our solutions under the ASSA ABLOY brand. Our products and services are dedicated to satisfying end-user needs for safe, secure, convenient and sustainable operations.

This manual is also suitable for:

Rd4Cdc 4

Table of Contents