3 7
Mount Track
If opening angle greater than 125°, spring cushion stop cannot be used and an auxiliary stop
by others is required.
!
Set Screws
toward hinge
A) Insert slider into track.
B) For openings 125°or less, insert spring
cushion stop on hinge side of track .
For openings greater than 125°, omit
spring stop.
3 8
Connect Arm to Track
Open Latch & Sweep Valves
with 1/8" wrench provided.
3 9
Closer Spring Adjustment
Closing Force
Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
C
Secure arm to slider
assembly using 3/16"
wrench. Turn wrench
counter clock wise to
tighten.
+
Stronger
A
B
C) Insert end caps (both ends).
D) Secure track to door using screws
provided.
E) Snap on cover.
HINGE
11/16"
Wrench
Weaker
9
D
E
Open door to maximum desired swing
minus 5° and hold. Slide spring
cushion stop assembly against slider
assembly and secure to track using
5/64" or 2mm wrench.
Slowly increase closer power
until door closes consistently. A
closer set to the ADA required 5
lbs opening force may not be
strong enough to close the door
due to latching hardware, air
pressure, or frame issues.
80-9372-0100-015 (02-14)
®