Cabling And Setup - Extron electronics VTT001 User Manual

Hide thumbs Also See for VTT001:
Table of Contents

Advertisement

Installation, cont'd

Cabling and Setup

To install the VTT001 MAAP, VTT001 AAP, VTT001 models and
the VTR001 MAAP, VTR001 AAP, VTR001 models, follow these
steps:
1.
2.
1&2
Figure 2-5 — RJ-45 pin terminations
VTT001 and VTR001 • Installation
2-6
Turn all of the equipment off and, if applicable, disconnect
it from the power source.
Connect the RJ-45 connectors of the transmitter and
receiver to either end of the UTP cable. See
testing" and
"Equalizing pair
RJ-45 termination must comply with the TIA/EIA
T568A or TIA/EIA T568B wiring standards for all
connections, as shown on the following page.
Pins:
12345678
Pin
1
White-green
2
Green
3
White-orange
4
Blue
5
White-blue
6
Orange
7
White-brown
8
Brown
7&8
3&6 4&5
Twisted Pairs (4)
RJ-45
Connector
For best results, use Extron Skew-Free
cable, available in bulk or in various preterminated
lengths. If necessary, regular CAT 5 cable may be used.
CAT 5e and CAT 6 cables are not recommended.
If you are using Enhanced Skew-Free
the TIA/EIA T-568-A standard only.
skew" in this chapter.
TIA/EIA T568A
TIA/EIA T568B
Wire color
Wire color
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
"Cable
RGB Video
Signal
Red/V. sync +
Red/V. sync -
Power
Green +
Green -
Power
Blue/H. sync +
Blue/H. sync -
A/V UTP
A/V cable, use

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vtr001

Table of Contents