Download Print this page
Extron electronics MTP 1500RL 15HD RS SEQ Setup Manual
Extron electronics MTP 1500RL 15HD RS SEQ Setup Manual

Extron electronics MTP 1500RL 15HD RS SEQ Setup Manual

Twisted pair receiver
Hide thumbs Also See for MTP 1500RL 15HD RS SEQ:

Advertisement

Quick Links

MTP 1500RL 15HD RS SEQ • Setup Guide
This guide provides basic instructions for an experienced installer to set up and operate the Extron MTP 1500RL
15HD RS SEQ twisted pair receiver.
For full details, see the MTP 1500RL 15HD RS SEQ User Guide, available online at www.extron.com.
SELECT
BUFFERED OUTPUT
INPUT
POWER
12V
1.0A MAX
MTP
MTP

Installation and Setup

Step 1 — Mounting
Turn off or disconnect all equipment power sources. Mount the MTP 1500RL 15HD RS SEQ receiver as required.
Step 2 — Connect Input
Connect the RJ-45 cable from an MTP transmitter to the Input port on the MTP 1500RL 15HD RS SEQ receiver.
Terminate the cable as shown below right, using the same standard (T568A or T568B) at both ends.
Transmission distance with one device before the MTP 1500RL 15HD RS SEQ
1500 feet (457 m) maximum (video signals)
VGA
Input
MTP Tx
cable
Source
Device
1000 feet (305 m) maximum
Transmission distance with more than one device before the MTP 1500RL 15HD RS SEQ
1500 feet (457 m) maximum (video signals)
VGA
Input
MTP Tx
cable
cable
Source
Device
NOTE: The transmitter and receiver are designed for and perform best with Extron Enhanced Skew-Free
with the TIA/EIA T568A standard. CAT 5 cables are acceptable but less preferable. Using preterminated and tested cables is also
recommended. Cables terminated on site should be tested before use to ensure that they comply with Category 5 specifications.
Step 3 — Connect Outputs
Attach the applicable output cables (video, audio, and buffered output).
A.
High resolution video output — Connect a suitable display device to the 15-pin HD
connector (RGB).
B.
RS-232 connector — Connect an RS-232 compatible MTP transmitter to the 3-pole
captive screw connector (wired as shown at right) for bi-directional or uni-directional
communication up to 1,000 feet, (305 meters) maximum.
C.
Buffered output — Connect up to 5 daisy-chained MTP receivers to this RJ-45 connector.
Step 4 — Receiver DIP Switches
H sync (H+) and V sync (V+) switches — Set these switches up (On) for positive sync or
down (Off) for negative sync.
Composite Sync, SOG, and Video switches — Set these switches as shown in the table
(see right) to output the indicated format.
End Unit switch — Set this switch up if either of the following is true:
The receiver being configured is the only receiver connected to the transmitter.
The receiver being configured is the last receiver in a daisy-chained system.
BI-232 switch — Set this up (ON) for bi-directional or down for uni-directional communication.
RED
LEVEL
PEAKING
GREEN
BLUE
ADJUST
DELAY
RGB
OUTPUT
MTP
MTP
TP
cable
MTP 1500RL
15HD RS Device
(RS-232 data signals)
TP
TP
MTP RL Rx
MTP 1500RL
cable
Device
15HD RS Device
1000 feet (305 m) maximum
(RS-232 data signals)
MIN/MAX
MTP 1500RL SERIES
RS-232
ON
MTP 1500RL 15HD RS SEQ
Tx
Rx
VGA
cable
Display
RJ-45 Connector
VGA
cable
Display
Pin
T568A Wire
Color
1
White-green
Pins:
2
Green
12345678
3
White-orange
4
Blue
5
White-blue
6
Orange
7
White-brown
Insert Twisted
8
Brown
Pair Wires
AV cable terminated in accordance
Connected RS-232
Device Pins
Receive
Transmit
Ground
Output
C Sync SOG Video
Format
RGBHV
RGBS
RGsB
Component*
S-video*
Composite*
* Input video format must match.
T568B Wire
Color
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
MTP Reciever
Pins
Tx
Rx
Gnd
ON

Advertisement

loading

Summary of Contents for Extron electronics MTP 1500RL 15HD RS SEQ

  • Page 1: Installation And Setup

    Step 2 — Connect Input Connect the RJ-45 cable from an MTP transmitter to the Input port on the MTP 1500RL 15HD RS SEQ receiver. Terminate the cable as shown below right, using the same standard (T568A or T568B) at both ends.
  • Page 2 Plug them into all units. Grounding guidelines 3/16" (5 mm) Extron MTP 1500RL 15HD RS SEQ products can be adversely affected by electrostatic discharge (ESD) Max. if they are not grounded correctly. Wrap To prevent malfunctions or product damage, an experienced installer can correctly ground an Extron SECTION A–A...