Download Print this page

Rebuild Array - Promise Technology FASTTRAK66 User Manual

Hide thumbs Also See for FASTTRAK66:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Manual EN
05-08-1999 11:30
FastBuild™ Configuration Setup
Rebuild Array <5>
The Rebuild option is necessary to recover from an error in a mirrored disk
array. Note: Drives must be replaced if they contain any physical errors.
Follow these steps before using the <5> Rebuild Array menu option:
1) From the FastTrak66 Startup BIOS error message, identify which array has
failed.
2) In the FastBuild™ Setup <3> Define Array, select the failed array and
identify the Channel and ID of the failed drive
3) Power off and physically remove the failed drive
4) Replace the drive with an identical model
5) Continue the restoration process with the <5> option
With a failed drive in a disk array, Rebuild Menu will show the status as
"Critical".
Fastbuild™ Utility 1.xx (c) 1995-99 Promise Technology, Inc.
Array No. RAID Mode Total Drv Capacity (MB)
Array 1
Stripe
Array 2
Mirror
Array 3
------
Array 4
------
[ ] Up [ ] Down [ESC] Exit [ENTER] Select
Pagina 27
[ Rebuild Array Menu ]
2
13044
2
6522
------
------
------
------
[Keys Available]
27
Status
Functional
Critical
------
------