Apache Ecu Connections (My 2017 & 2018) - Raven Hawkeye 2 Installation Manual

For et apache sprayers my 2017+
Hide thumbs Also See for Hawkeye 2:
Table of Contents

Advertisement

ET APACHE ECU CONNECTIONS (MY 2017 & 2018)
1. Locate the Hawkeye ECU cable harness (P/N 115-7303-143) provided in the kit.
2. Locate the four 12-pin Deutsch connectors (one of each: gray, black, green, brown) grouped together, and
connect them to the matching connectors of the RCM - Sprayer adapter cable (P/N 115-2005-095) previously
installed.
3. Connect the four pin ISObus plug from the cab to the four pin receptacle ISObus connector on the Hawkeye
ECU harness (P/N 115-7303-143).
FIGURE 6. ISOBus Connector
ISOBus
Connector
4. Connect the three pin plug to existing pressure transducer in the boom plumbing.
FIGURE 7. Pressure Transducer.
RCM - Sprayer Mounting and Connection: Install the RCM - Sprayer Cables and System Power Cables
RCM - SPRAYER MOUNTING AND CONNECTION
Pressure Transducer
35