3
The instructions in this manual are designed to assist in the proper installation of the AccuBoom system on
RoGator Liquid/AirMax 180 and TerraGator Liquid/AirMax/AirSpread series sprayers. Refer to your computer's
Installation & Operation Manual for instructions on setting up the software and using the AccuBoom system.
IMPORTANT:
When running a combination liquid/spinner spreader TerraGator, it is necessary to uninstall the AccuBoom
system from the machine when switching from liquid to spinner spreader applications.

INSTALL THE BOOM VALVE CONNECTIONS

FIGURE 1. Access Panel Cover and Bulkhead Panel Access Hole
1. Locate the access panel on the right-rear corner outside the cab and remove the cover.
2. Locate the bulkhead panel access hole in the cab and remove the plug.
3. Insert the AccuBoom harness cable (P/N 115-2001-018 or 115-2001-058) into the bulkhead panel access hole so
that the two CAN node connections protrude from the access hole inside the cab.
NOTE:
It may be easier to route the node connections through the access panel outside the cab rather than
routing the entire cable through the access hole from within the cab.
Manual No. 016-1001-063 Rev. E
A CCUBOOM INSTALLATION
C H A P T E R 3
Bulkhead Panel
Access Hole
Removed Plug
Access Panel
9