HYOSUNG MoniMax 5600T Operator's Manual page 141

Table of Contents

Advertisement

MoniMax 5600T
G.2 Wall Cutting preparation
The wall should be prepared according to the following guidelines before installing MoniMax 5600T.
1) The maximum thickness of wall that enables you to install this machine should not be exceeded
250mm (10 inch).
2) The height of this machine indicated on the plan is minimum height, it can be adjusted up to 30mm
(1.18 inch). (Only for Adjustor Type)
3) The installation of this machine is based on the floor from customer's foot of outside building.
4) After installation this machine, the gap between collar and wall will be waterproofed by using of
silicon.
5) "The minimum maintenance space" should be secured in the rear of this machine.
6) All the measurements shown on the plan, ±5mm (0.2 inch) tolerance should be kept.
Fig. 6.8 (a) Wall construction plan (Adjustor Type)
Note : All the unit in the dimension is millimeter and ( ) is inch.
☞ "A" section can be adjusted up to 80mm.
Install the ATM considering the height
adjustment of the ADJUST (FOOT).