Error
Code
Dark light sensor test error (CS13)
400E100
during initializing.
Dark light sensor test error (CS21A,
400E200
CS21B) during initializing.
Dark light sensor test error (CS31A,
400E300
CS31B) during initializing.
Dark light sensor test error (CS41A,
400E600
CS41B) during initializing.
Dark Light Test Error (CS10, CS9)
400E700
during initializing
Dark light sensor test error (CS14,
400E800
CS10) during initializing.
Dark
light
400EA00
(CS18,28,38,48).during initializing.
Not supporting the command for
400EB00
Auto Sensor.
Cause
sensor
test
error
1. Check if a sensor is mounted.
2. If error occurs when checking CS13(CDU B/D CN10
#1~4) cable operation, replace a sensor.
1. Check if each sensor is mounted.
2. If error occurs when checking CS21A (cable
operation, replace a sensor.
3. If error occurs when checking CS21Bcable operation,
replace a sensor.
1. Check if each sensor is mounted.
2. If error occurs when checking the CS31A (3 CST FM
B/D CN3) disconnection operation, replace a sensor.
3. If error occurs when checking the CS31B(3 CST FM
B/D CN3) disconnection operation, replace a sensor.
4. Check if the CDU Board CN6 and 3 Cassette FM
Board CN1 are connected.
5. Check settings of 3 Cassette FM Board Dip Switch
(#2, #4, #6 On)
1. Check the CDU information setting (4 Cassettes).
2. Check if each sensor is mounted.
3. If error occurs when checking the CS31B(4 CST FM
B/D CN3) disconnection operation, replace a sensor.
4. Check if 3 Cassette FM B/D CN2 and 4 Cassette FM
B/D CN1 are connected.
5. Check settings of 4 Cassette FM Board Dip Switch
(#3, #5, #6 On)
6. If error occurs when checking the CS31A (4 CST FM
B/D CN3) disconnection operation, replace a sensor.
1. Check if each sensor is mounted.
2. If error occurs when checking CS 10 disconnection
operation, replace a sensor.
3. If error occurs when checking CS 9 disconnection
operation, replace a sensor.
1. Check if each sensor is mounted.
2. If error occurs when checking CS14 cable operation,
replace a sensor.
3. If error occurs when checking CS10 cable operation,
replace a sensor.