HYOSUNG MoniMax 5600T Operator's Manual page 128

Table of Contents

Advertisement

MoniMax 5600T
Error
Code
Abnormal
4009800
during check dispense operation
CIU
communications
4009900
timeout error during check dispense
reserved operation or initializing.
CIU
communications
4009A00
timeout error during check dispense
reserved operation or initializing.
Detected the CS31A and CS31B
4009B00
Dark during initializing or dispense
reserved operation
Detected the CS31B Dark during
4009C00
initializing
operation
3
Cassette
4009D00
dispense reserved operation
Mounting/demounting
4009E00
during dispense operation
Cause
CIU
detecting
sensor
response
response
or
dispense
reserved
not
available
during
3
Cassette
1. Clean CS31AB and CS41AB, or remove foreign
objects.
2. Check if the FM Board (3 CST or 4 CST) CN3 and
CIU Sensor Cable are connected.
1. Reinitialize
2. Check if the CIU communications serial cable is
connected.
3. Check if the CIU power cable is connected.
The same as #40099 handling.
1. Remove the remaining notes and foreign objects at
the position of the CS31A and CS31B sensors.
2. Check settings of 3 Cassette FM Board Dip Switch
(#2, #4, #6 On)
3. Check if the CS31 and CS31B Sensor Cable are
disconnected
4. Exchange a sensor after abnormal operating the
CS31A, CS31B sensor
1. Remove the remaining notes and foreign objects at
the position of the CS31B sensor.
2. Check settings of 3 Cassette FM Board Dip Switch
(#2, #4, #6 On)
3. Check if the CS31B and CS31B sensor cables are
disconnected
4. Exchange a sensor after abnormal operating the
CS31B.
1. Mount 3 cassette
2. Check if the CDU Board CN6 and 3 Cassette FM
Board CN1 are connected.
3. Check settings of 3 Cassette FM Board Dip Switch
(#2, #4, #6 On)
4. Check if the CS37 sensor cables are disconnected (3
CST FM B/D CN3).
5. Exchange a sensor after abnormal operating the
CS37 sensor .
1. Check notes' status in 3 Cassette
2. Check 3 cassette specifications
3. Check if the CDU Board CN6 and 3 Cassette FM
Board CN1 are connected.
4. Check settings of 3 Cassette FM Board Dip Switch
(#2, #4, #6 On)
5. Check if the CS37 sensor cable are disconnected (3
CST FM B/D CN3).
6. Exchange a sensor after abnormal operating the
CS37 sensor .