Basic principles, overview and ordering information
2.20.6 Optional functions of
The optional functions can be activated via the control data. The functions are
available for each counter.
The functions of the input terminals COUNT- can be modified:
1. Deletion of counter content (DELETE)
2. Selection of counting direction (DIRECTION)
Threshold comparison with rapid output signals (ON delay approx. 0.02 ms, OFF
delay approx. 0.2 ms).
Two variants for comparison of threshold value:
1. Count < threshold value
2. Count >= threshold value
When using the module for 2 x 32 bit counters, 2 threshold values can be
preselected.
Interference
200 Hz, 2 kHz, 20 kHz, 200 kHz.

2.20.7 Complete control data from PLC to module (outputs)

5 words are transmitted from the PLC to the module. The first 4 words have
various meanings depending on word 5.
4 x 16 bit counters (Word 5, Bit 11 = 0)
Word 1
Word 2
X
X
Count of counter
X
1
X
Count of counter
2
X
X
X
X
Count of counter
Count of counter
1
2
Threshold 1 of
Threshold 1 of

counter 1

counter 2
Overwrite data of
Overwrite data of
counter 1 *
counter 2 *
Configuration
Configuration
data of counter 1
data of counter 2
*
*
X: Any word value
b: Binary display *: See below for details
*Word 3 and word 4 are not transmitted at a set data width of 3. Word 5 is then
transmitted as word 3.
76
ricos
COUNTER
suppression
with
Word 3*
X
X
X
Count of counter
3
X
Count of counter
3
Threshold 1 of
counter 3
Overwrite data of
counter 3 *
Configuration
data of counter 3
*
x: Any bit value
LSB: Least Significant Byte
© 2002 Wieland Electric GmbH Version 2.4* (December 2002)
digital
filters
Word 4*
Word 5
X
0000 0000 xxxx xxxx
b
X
xxx1 0000 xxxx xxxx
b
X
xx1x 0000 xxxx xxxx
b
X
x1xx 0000 xxxx xxxx
b
Count of counter
1xxx 0000 xxxx xxxx
4
b
Count of counter
1111 0000 xxxx xxxx
4
b
Threshold 1 of
xxxx 0001 xxxx xxxx
counter 4
b
Overwrite data of
xxxx 0011 xxxx xxxx
counter 4 *
b
Configuration
xxxx 0100 xxxx xxxx
data of counter 4
b
*
MSB: Most Significant Byte
Part no. 05.591.3389.0
for
No effect i.e. no data
is loaded into the
module
Load counter 1
Load counter 2
Load counter 3
Load counter 4
Load counters 1 to 4
Load threshold 1
(counters 1 to 4)
Load overwrite data
(counters 1 to 4
Load configuration
data (counters 1 to 4)