Cue-lists Playbacks
The times for Cue-list playbacks are illustrated in the graphic on
the right.
Delay in and delay out times will start together. Fade in time
starts after delay in is finished, while fade out time starts after
delay out has finished.
Fade out is only used on dimming channels. Fade out time will
be used as delay out between the steps if the coming step does
not have a dim off effect.
Cue Playbacks
0
7.5.2 Set Individual Attribute Times
Attributes have only delay in and fade in times. You can switch to other attributes by pressing the attribute keys.
After setting the attribute times, those attributes will not use the global time unless you press [Use Global].
• Press [Use Global] if you want the selected attribute times to revert to use to global time.
• Press [Attribute Time Use Global] if you want all attribute times revert to using to global time.
Enigma™ M4 Manual - Rev A
0
D
The times for Cue playback are illustrated in the graphic
on the left.
There is no delay out time if it is a Cue playback.
When fading in the playback, the fade in time starts to run
after delay in is finished. When fading out the playback,
fade out time starts to run immediately.
Time (s)
Page 31
Time (s)