Installation - Wilo Yonos GIGA-N 80 Installation And Operating Instructions Manual

Table of Contents

Advertisement

10.6

Installation

10.6.1
Installing the shaft/bearing
bracket
Installation and operating instructions Wilo-Yonos GIGA-N
Maintenance/repair
NOTICE
The electronic module must be dismantled and installed according to the
instructions enclosed with the spare part!
CAUTION
Risk of material damage due to lack of ventilation of the electronic mod-
ule!
For motor power of ≥ 11 kW, the electronic module has a built-in speed-controlled
fan for cooling. The fan switches on automatically if the heat sink reaches 60 °C.
The fan draws in air from the outside, which is guided over the outer surface of the
heat sink. It only runs when the electronic module is operated under load. Depending
on the prevailing ambient conditions, dust is sucked in by the fan, which can accu-
mulate in the heat sink.
• Check the electronic modules from 11 kW for contamination at regular intervals.
• Clean fan and heat sink if required.
Installation must be carried out based on the detailed drawings in the section "Dis-
mantling" as well as the general drawings in the section "Spare parts".
ƒ
Clean and check the single components for wear before installation. Damaged or
worn parts must be replaced with original spare parts.
ƒ
Coat location points with graphite or something similar before installation.
ƒ
Check the O-rings for damage and replace if necessary.
ƒ
Flat gaskets must be constantly replaced.
DANGER
Risk of fatal injury due to electrical current!
Improper conduct when carrying out electrical work can lead to death due to electric
shock!
• Any work on electrical devices may only be carried out by a qualified electrician.
• Before carrying out any work, disconnect the unit from the power supply and
secure it against accidental switch-on.
• Any damage to the pump connection cable should only ever be rectified by a
qualified electrician.
• Observe the installation and operating instructions for the pump, motor and
other accessories.
• Never poke around in the electronic module or motor openings or insert any-
thing into them.
• Never operate the pump without the electronic module being installed.
• Reinstall any uninstalled safety devices, such as module or coupling covers,
once the work is complete.
NOTICE
Observe the drawings in the section "Spare parts".
4.1A
Fig. 53: Shaft
3.1
4.1B
en
59

Advertisement

Table of Contents
loading

Table of Contents