Wilo Yonos GIGA-N 80 Installation And Operating Instructions Manual page 31

Table of Contents

Advertisement

1.5 ... 4 kW:
SSM
SBM
Fig. 26: Connect shield
Installation and operating instructions Wilo-Yonos GIGA-N
Installation and electrical connection
Connect shield in/on electronic module
5.5 ... 7.5 kW:
1
2
M12
3
4
ƒ
With a motor power of < 5.5 kW: in the electronic module on the earth rails
ƒ
With a motor power of 5.5 kW and 7.5 kW: on the cable gland
ƒ
With a motor power of ≥ 11 kW: on the cable terminals above the terminal strip
In order to ensure drip protection and strain relief on the cable connections, only cables
with a suitable outer diameter may be used (for the required cross-section, please see
the table "Cable cross-sections").
Secure cable glands tightly.
Ensure that no drips can run into the electronic module:
ƒ
Bend the cables into a drain loop near the threaded cable gland
ƒ
Unused cable glands should be sealed with the sealing washers provided and
screwed tight.
The mains cable should be laid in such a way that it can under no circumstances come
into contact with the pipe and/or the pump and motor housing. When pumps are used
with fluid temperatures above 90°C, a mains cable with suitable thermal resistance
must be used.
Note additional earthing!
Tightening torques for union nuts of the threaded cable glands
Thread
M12x1.5
M16x1.5
M20x1.5
M25x1.5
M40x1.5
Table 11: Tightening torques for threaded cable glands
11 ... 22 kW:
Tightening torque
[Nm] ± 10 %
3.0
6.0
8.0
11.0
16.0
en
Installation information
1x threaded cable gland
M12 reserved for connect-
ing cable for an optional
differential pressure sensor
31