Installation and operating instructions Wilo-Yonos GIGA-N
Faults, causes and remedies
interference signal on the communication lines that exceeds the applicable standard
values. The pump can only return to normal operation once the source of interference is
remedied.
E000
In the event of a fault, the error page is displayed instead of the status page.
5.0.0.0
You can then navigate as follows:
ƒ
To change to the menu mode, press the operating button. Menu number
<6.0.0.0> flashes on the display. By turning the operating button, it is possible to
navigate in the menu as usual.
ƒ
Press the operating button. Menu number <6.0.0.0> is displayed without
flashing. On the units display, the current incidence (x) as well as the maximum in-
cidence of the error (y) are displayed in the format "x/y". Until the error can be ac-
knowledged, pressing the operating button again will cause a return to menu mode.
NOTICE
A 30-second timeout causes the display to revert to the status page or error page.
Each error code has a separate error counter that counts all incidences of the error
within the last 24 hours.
The error counter is reset manually, 24 hours after "Mains ON" or when "Mains ON"
is repeated.
Program step/query
1
2
3
4
Table 27: Error type A
Contents
ƒ
Error code is displayed
ƒ
Motor Off
ƒ
Red LED On
ƒ
SSM is activated
ƒ
Error counter is increased
> 1 min?
Error acknowledged?
End; auto control resumes
Yes
No
en
71