9

Shutdown

9.1
Switching off the pump and tem-
porary shutdown
9.2

Shutdown and storage

10

Maintenance/repair

Installation and operating instructions Wilo-Yonos GIGA-N
Shutdown
Type Symbol
Values/explanations
Access disable feature active (no changes
possible) (for additional information, see
"Activating/deactivating access disable"
chapter)
CAUTION
Risk of material damage due to overheating!
Hot fluids can damage the pump seals when the pump is at a standstill.
After deactivating the heat source:
• Allow the pump to run until the fluid temperature has dropped to an appropriate
level.
CAUTION
Risk of material damage due to frost!
If there is a danger of frost:
• Drain the pump completely to avoid damage.
ƒ
Close the shut-off device in the pressure pipe. If a non-return valve is installed in
the pressure pipe and counterpressure is present, the shut-off device can remain
open.
ƒ
Do not close the shut-off device in the suction line.
ƒ
Switch off the pump.
ƒ
If there is no danger of frost, make sure the fluid level is sufficient.
ƒ
Operate the pump every month for 5 minutes. Doing this prevents deposits from oc-
curring in the pump compartment.
WARNING
Risk of injury and damage to property!
• Dispose off the pump contents and rinsing fluid by taking the legal regulations
into account.
• Always wear protective clothing, protective gloves and protective goggles when
working.
ƒ
Clean the pump thoroughly prior to storage!
ƒ
Drain the pump completely and rinse thoroughly.
ƒ
The remaining fluid and rinsing fluid should be drained, collected and disposed off
via the drain plug. Observe local regulations along with the notes under "Disposal"!
ƒ
Spray the interior of the pump with a preservative through the suction and discharge
ports.
ƒ
Close the suction and discharge ports with caps.
ƒ
Grease or oil the blank components. For this, use silicone-free grease or oil. Observe
the manufacturer's instructions for preservatives.
It is recommended to have the pump serviced and checked by the Wilo customer ser-
vice.
Maintenance and repair work require the pump to be partially or completely dismantled.
The pump housing can be installed in the piping.
Display conditions
en