LM16-20-25 I&M MANUAL/EN/11.30.2010
2.7

Three Phase Power Connections

Figure 2. Three Phase Control Box Power Connections
PS – Power supply
TR – Trolley connection
PB – Pushbutton connection
1. Remove the control enclosure cover.
2. Insert the power supply cable through the cable gland or connector (PS).
3. Connect phases L1, L2, L3, and ground (PE) to terminal strip. Refer to the wiring diagram.
4. Tighten the terminal screws
5. Tighten the cable gland or connector to secure the cable.
6. Connect the pushbutton assembly to plug connector X23 (PB).
7. Connect the motorized trolley plug connector X24 (TR) (optional).
8. Close the control enclosure cover.