AGM the blink code is Amber-Green-Green. For Gel the blink code is Amber-Green-
Green-Green.

Branch Circuit Rating (LPC only)

The branch circuit rating ("BCR") can be set to 0, 5, 10, 15, or 20A. If set to 0A, the
charger will not enable. Bypass will still be available. The default factory setting is 15A.
The BCR may be changed at the factory or by the CAN configuration interface.

AC Line Qualify Time (LPC only)

The AC line qualification time can be set to any value between 5 and 60 seconds, in 1
second increments. This default setting is 30 seconds. This setting adjusts the time that
it takes for the charger and bypass to start once qualified AC power has been applied to
the charger input. This setting may be changed at the factory or with the CAN
configuration interface.

CAN Instance and Baud Rate

The CAN instance (address) can be changed from 1 – 13. This is useful if there are
multiple inverters being used on the same CAN network. Multiple inverters should not
share the same CAN instance. The Baud Rate may be changed between 250k and 500k.
The default settings for the inverter are Instance 1 and Baud Rate 250k. These values
may be changed at the factory or by the CAN configuration interface.
NOTE: In the highly unlikely chance that an internal error occurs to the memory of
the inverter/charger, the inverter/charger configuration will reset to the
12LPC15 standard. All settings will revert to the standard default
configuration, except the battery setting will be set to GEL.
 
 
 
122221 12LPC15 Manual Rev A.docx 