Battery Options (LPC Only)

The charger can be set to charge three different types of batteries: wet lead-acid, AGM, or gel. The charger is set
to AGM by default by the factory. The battery type may be changed at the factory or by the NVM Setup Utility. To
determine what type of battery the inverter is configured for, monitor the LED blink code at startup and reference
the LED status chart.

Branch Circuit Rating (LPC Only)

The branch circuit rating (BCR) can be set to 0, 5, 10, 15, or 20 A. If set to 0 A, the charger will not enable, but
bypass power will still be available. The default factory setting is 15 A. The BCR may be changed at the factory or
by the NVM Setup Utility.

AC Line Qualify Time (LPC Only)

The AC line qualification time is the setting that adjusts the time that it takes for the charger and bypass to start
once qualified AC power has been applied to the charger input. This time can be set to any value between 5 and 30
seconds, in 5 second increments. The default setting is 15 seconds This setting may be changed at the factory or
with the NVM Setup Utility.

CAN Instance and Baud Rate

The CAN instance can be changed from 1 – 13. This is useful if there are multiple inverters being used on the same
CAN network. Multiple inverters should not share the same CAN instance. The baud rate may be changed between
250 k and 500 k. The default settings for the inverter are Instance 1 and Baud rate 250k. These values may be
changed at the factory or by the NVM Setup Utility.
NOTE: In the highly unlikely chance that an internal error occurs to the memory of the inverter/charger, the
inverter/charger configuration will reset to the 12LPC15 standard. All settings will revert to the standard default
configuration, except the battery setting will be set to gel.