BACKGUARD INSTALLATION

The backguard is located as shown in Fig. 15. Secure
the backguard to the wall behind the range. Specific
instructions for installation of the full backguard or
low backguard can be found packaged with the
backguard. See also page 8, "Planning The Instal-
lation" section. A backguard must be installed when
there is less than a 12" clearance between
combustibles and the back of the range (above the
cooking surface). See Fig. 14. DCS backguards are
sold separately.

ELECTRICAL CONNECTIONS

ELECTRICAL CONNECTIONS
Power Requirements Range:
120 VAC, 60 Hz., single phase. 4 Amp Max. (Use 15 Amp Circuit)
Always disconnect electric supply cord from the wall outlet or service
disconnect before servicing this appliance. Observe all governing codes
and ordinances when grounding, in absence of which, observe National
Electrical Code ANSI / NFPA No. 70-1990.
RECOMMENDED GROUNDING METHOD
This appliance is factory equipped with a power supply cord with a
three-prong grounding plug (with polarized parallel blades). It must be
plugged into a mating grounding, type receptacle, connected to a
correctly polarized 120 volt circuit. If the circuit does not have a
grounding type receptacle, it is the responsibility and obligation of the
installer to have the existing receptacle changed to a properly grounded and polarized receptacle in accordance
with all applicable local codes and ordinances by a qualified electrician. In the absence of local codes and
ordinances, the receptacle replacement shall be in accordance with the National Electrical Code.
Note:
The third prong should not, under ANY circumstances, be cut or removed.
WALL MOUNT
FULL BACKGUARD
(MODEL # BGS-3030)
WALL MOUNT
LOW BACKGUARD
(MODEL # BGS-1230)
Fig. 15
Receptacle Box
Cover Plate
Three
Prong
Plug
Three Prong
Receptacle
Fig. 16
1-5/16"
28-1/8"
10-1/8"
2"
15