3- 11.4 Auto Checking - Vivotek AW-GEV-264A Series User Manual

L2 managed poe switch
Table of Contents

Advertisement

3- 11.4 Auto Checking

This page allows the user to specify the auto detection parameters to check the linking status
between PoE ports and PDs. When it detected the fail connect, will reboot remote PD
automatically.
Web Interface
To Display Power Over Ethernet Auto Checking in the web interface:
1.
Click Configuration, PoE, and Auto checking.
2.
Enable the Ping Check function.
3.
Specify the PD's IP address, checking interval, retry time, failure action and reboot time.
4.
Click Apply to apply the change.
Figure 3-11.2: The PoE Scheduling
Parameter description:
Power Supply Configuration
Ping Check :
Enable Ping Check function can detects the connection between PoE port and power
device. Disable will turn off the detection.
Port :
This is the logical port number for this row.
Ping IP Address :
The PD's IP Address the system should ping.
Start up Time(sec) :
When PD has been start up, the Switch will wait Start up time to do PoE Auto Checking.
default: 60, range: 30-600 sec.
Interval Time(sec) :
Device will send checking message to PD each interval time. default: 30, range: 10-120
sec.
Retry Time :
When PoE port can't ping the PD, it will retry to send detection again. When the third time, it
User Manual rev. 1.2. Aug. 2015
133

Advertisement

Table of Contents
loading